Fire panels play a critical role in protecting lives and property in Australia. They ensure timely detection of fire hazards and facilitate swift responses. However, using the wrong battery in these systems introduces a significant and often overlooked risk.
From gas build-up to acid leaks and even catastrophic explosions, incorrect batteries can transform fire protection systems into a safety hazard. Let’s explore why this happens, the role of correct charging and maintenance, and how Valen’s ActivFire-certified AGM “Topin” range provides the best solution for reliable and safe operation.
The Danger of Using Incorrect Batteries in Fire Systems
Fire systems rely on batteries to provide power during emergencies. Unfortunately, using incompatible or substandard batteries can lead to gas build-up inside the battery, creating a serious risk:
- Gas Build-Up and Rupture: Incorrect batteries may not effectively control internal pressure, leading to gas build-up. If ignited, the gases can cause the battery casing to rupture or explode.
- Hazardous Acid Release: The corrosive acid within batteries can cause severe harm to skin and eyes. If inhaled or ingested, the consequences can be fatal.
- No Warning Signs: Gas build-up often occurs without warning, leaving personnel at risk of injury or worse. This unpredictability amplifies the danger.
The issue isn’t just theoretical. Inadequate batteries, poor charging practices, and lack of maintenance continue to expose personnel and sites to unnecessary risks across Australia.
The Impact of Incorrect Charging and Maintenance
Battery-related hazards are not limited to using the wrong battery type; incorrect charging and maintenance compound the issue. Fire pump systems, for example, require a temperature-compensated charger to regulate the battery’s voltage. Without this:
- Incorrect charging can accelerate gas build-up within the battery.
- Overcharging or undercharging leads to battery failure, reducing reliability during emergencies.
- Batteries may dry out or overheat, increasing the likelihood of rupture or explosion.
Australian standards highlight the importance of proper signage, correct charging, and battery maintenance to mitigate these risks.
Standards for Fire Pump Battery Systems in Australia
The Australian Standard AS 2941-2008 outlines essential requirements for battery safety and maintenance within fire pump systems. Clause 3.13.6 specifically mandates a warning sign to be fixed adjacent to batteries serving fire pumpsets. This ensures that personnel are aware of the hazards and take necessary precautions.
In addition, AS 2941-2008 references AS 4029 for stationary lead-acid batteries, which consists of:
- AS 4029.1: Vented lead-acid batteries (flooded types).
- AS 4029.2: Valve-regulated lead-acid batteries (AGM type).
- AS 4029.3: Pure lead positive pasted plate batteries.
While non-certified batteries pose risks, FPA Australia recognizes that the danger can be significantly reduced if the following conditions are met:
- The battery is correctly maintained.
- The battery is of the Absorbed Glass Mat (AGM) type.
Why Valen’s ActivFire-Certified AGM Batteries are the Best Choice
Valen’s Topin AGM batteries, certified under the ActivFire scheme, are specifically designed for fire systems. Here’s why they are the ideal solution:
- Sealed and Maintenance-Free:
AGM technology eliminates the need for electrolyte maintenance. A built-in pressure relief valve safely releases any gas build-up, significantly reducing explosion risks.
- Reduced Risk of Acid Leaks:
Unlike flooded batteries, Valen’s AGM batteries are sealed, preventing acid leaks that could harm personnel or equipment.
- Temperature Compensation Compatibility:
Topin AGM batteries are designed to operate with temperature-compensated chargers, ensuring correct charging voltages and preventing gas build-up. This aligns with FPA Australia’s recommendations for fire systems.
- Float Charging Reliability:
With a float charge voltage range between 13.0 VDC and 13.8 VDC at 26.7°C, Valen’s AGM batteries meet the requirements for safe and reliable operation in fire systems.
- Compliance with Australian Standards:
Valen’s Topin range complies with relevant standards, giving peace of mind to installers, technicians, and site managers.
Enhancing Safety with Proper Induction and PPE
In addition to using the correct batteries, all personnel attending sites with fire systems should:
- Be correctly inducted and aware of battery hazards.
- Wear the appropriate Personal Protective Equipment (PPE) at all times, including gloves, eye protection, and face shields.
- Follow safety protocols to identify and mitigate risks when working near fire panels.
Partner with Valen for Safety and Compliance
At Valen, we understand the importance of delivering reliable, certified battery solutions for critical fire systems. Our ActivFire-certified Topin AGM batteries are designed to eliminate the risks of gas build-up, acid leaks, and system failures. By choosing Valen, you ensure:
- Compliance with Australian standards.
- Safety for personnel and equipment.
- Reliability during emergencies when it matters most.
Don’t take risks with your fire system. Ensure you’re using the best batteries for the job. Learn more about Valen’s Topin AGM range and how we can support your fire safety needs.
For additional resources, including safety guidelines and installation support, explore our website or contact our team.
Safety First. Reliability Always.