Intelligent Battery Tester (IBT) – Terminal Connectors

SKU: BT19071

Pair of terminal connectors for ACT battery testers, a spare or replacement set for connecting to battery terminals.

Attaching Intelligent Battery Tester clips directly to high resistance steel bolts will produce low, inaccurate Ah readings. These connectors must be used to obtain accurate, consistent Ampere-hour (Ah) readings on recessed battery terminals.

Price

+GST

Qty

Intelligent Battery Tester (IBT) – Terminal Connectors

Features

Applications

Specifications

SKUBT19071

Downloads

Download Specification Sheet

Download Information Sheet

Related Products

Frequently Asked Questions

What battery testing methods are recommended?

Three tiers. Impedance or conductance testing (instruments such as impedance meters) is fast, done on a live circuit, and reliably detects open cells, dry-out and connection degradation, but requires a baseline from when the bank…

Full answer: What battery testing methods are recommended?

Do I still need discharge testing if I have monitoring?

Yes, and this is where most monitoring vendors overclaim. Impedance and conductance are trend indicators, not capacity measurements. They catch open cells, dry-out and connection faults, and rising impedance correlates with capacity fade, but the…

Full answer: Do I still need discharge testing if I have monitoring?

What does AS 2676 require for battery maintenance and testing?

AS 2676 covers installation, maintenance, testing and replacement of secondary batteries in buildings, in two parts (vented and sealed cells). It is the standard Australian asset owners are audited against, and it is the correct…

Full answer: What does AS 2676 require for battery maintenance and testing?

How do I know when to replace a battery bank?

The usual convention is that a battery bank has reached end of life when it can deliver only 80% of its rated capacity. Below that point it can no longer be relied on to give…

Full answer: How do I know when to replace a battery bank?

How do I assess capacity on a single-bank zone substation where a discharge test is impractical?

This is the real problem. AusNet says full discharge and discharge-rate testing are “impractical on zone substations with a single battery bank”, which “prevent[s] accurate measurement of the DC system available capacity.” AusNet’s response is…

Full answer: How do I assess capacity on a single-bank zone substation where a discharge test is impractical?

More Sizing, testing and monitoring FAQs

Enquire Now

Login Required

An account is required to add products to your cart, please login or register for an account.