Home / Component Range / VRLA Batteries & Sealed Lead Acid Batteries / AGM Batteries / Topin AGM VRLA Batteries / Valen Topin 12V30Ah Battery
SKU: 12TP30
Valen Topin 12V30Ah is a rechargeable, deep cycle, Valve Regulated Lead Acid (VRLA) battery range. VRLA technology is commonly referred to as Sealed Lead Acid (SLA) as the battery electrolyte is suspended in Absorbent Glass Matting (AGM), in comparison to automotive type batteries where the electrolyte is loose. This construction ensures that the Valen Topin battery range is robust, safe and maintenance-free.

Premium (Valve Regulated Lead Acid) VRLA Design Valen Topin battery range can be installed and operated in any position (except inverted) making it an attractive option for less accessible areas Maintenance-Free Design Minimises technician time spent at site and on battery related callouts SSL Approval CSIRO certified for use in the Fire industry (AS 1603.4 Appendix G-1987) ActivFire Certificate: afp-1668 FAA and IATA Approved Valen Topin battery range is safe for air transportation
Diesel Genset Fire UPS Security Road Signage Automatic Gates Lifts & Elevators
| Voltage | 12 V |
|---|---|
| SKU | 12TP30 |
| Terminal | M5 |
| Length | 166 mm |
| Width | 126 mm |
| Height | 176 mm |
| C20 | 30 Ah |
| C10 | 27 Ah |
| C5 | 26.2 Ah |
| Capacity | 30 |
| Box Quantity | 1 |
Both are VRLA, valve regulated lead acid, meaning sealed valves and immobilised electrolyte with internal gas recombination, so they do not require watering and can be installed in a wider range of locations than a…
Full answer: What is the difference between AGM and gel batteries?
VRLA means the cell is sealed with a pressure relief valve and the electrolyte is immobilised, in a glass mat separator (AGM) or a thixotropic gel. Gas generated on charge recombines internally rather than escaping,…
Full answer: What is VRLA and what does “valve regulated” mean?
In order of impact: temperature (roughly 50% life reduction per 10 °C sustained above 20 °C), depth of discharge (the deeper the cycle, the shorter the life), sulphation from deep discharges and poor charging, dryout…
Full answer: What factors determine how long a VRLA battery lasts?
12 V is the nominal voltage; 7 Ah is the capacity measured over a 20-hour discharge. Discharged at 350 mA for 20 hours the battery delivers its rated capacity.It does not mean you can draw…
Full answer: What does a 12V 7Ah C20 rating mean?
Both are flat blade terminals on small VRLA batteries. F2 blades are wider than F1. They are not interchangeable without adapters, and getting it wrong is a common ordering error on replacement batteries. Larger stationary…
Full answer: What are F1 and F2 terminals?
An account is required to add products to your cart, please login or register for an account.