Home / Component Range / Uninterruptible Power Supply (UPS) / Online UPS / Vanguard 3000VA Online Tower UPS
SKU: PS80041
This unit is a 3kVA / 2700W online double conversion UPS for business, IT and telecom systems that cannot afford a power interruption. Incoming power is converted and rebuilt as a pure sine wave, giving zero transfer time and clean, stable output for servers and sensitive electronics. It carries a fuller load of servers, storage and network equipment in a small business or branch office. The tower design sits neatly on the floor beside the equipment it protects. Power factor correction with a 0.9 output power factor stabilises fluctuating voltage, and ECO mode reaches efficiency above 94% to reduce running costs. It runs on eight 12V 7Ah batteries, which recharge to 90% in 4 hours, and external battery packs can be added for longer runtime. An LCD control panel shows status at a glance, with RS232 and USB ports and an optional SNMP slot for remote monitoring. Overload, surge and short circuit protection, internal bypass and cold start come standard. Dimensions are 200 x 420 x 358 mm and weight is 30 kg.

Pure Sinewave Output with Double Conversion Topology
Designed for advanced mission-critical electronic devices
Hot Swappable Battery Replacement (Option)
High Efficiency Mode and Free-Run Mode Available
Overload, Surge, Short Circuit Protection
| Voltage | 230 V |
|---|---|
| SKU | PS80041 |
| Length | 225 mm |
| Width | 420 mm |
| Height | 358 mm |
Design life and service life are different numbers, and the gap is mostly temperature. A EUROBAT Long Life class VRLA is rated at 10–12 years on float at 20 °C. In practice: at 30 °C,…
Full answer: How long do UPS batteries last, and how often should they be replaced?
Watch for: runtime shorter than expected on a test or a real event individual battery voltages drifting from the string average internal impedance rising above the baseline taken at installation case swelling, terminal corrosion, cracking…
Full answer: What are the signs a UPS battery is failing?
There are three likely causes, in order: The battery has lost capacity. End of life is usually 80% of rated, and a bank at 60% gives only a fraction of its original runtime. The load…
Full answer: Why does my UPS only give a few minutes of runtime?
Impedance or conductance testing is performed on a live circuit and is the routine tool, fast, non-invasive, and reliable for detecting open cells, dry-out and connection degradation, provided you have a baseline from installation. What…
Full answer: How do I test UPS batteries without dropping the load?
It depends on your site. Lithium is worth serious consideration where: weight or floor loading is a constraint footprint limits the runtime you can fit the room runs hot enough that VRLA life becomes uneconomic…
Full answer: Should I move from VRLA to lithium in my UPS?
An account is required to add products to your cart, please login or register for an account.