Gel

Gel Monobloc Batteries

Valen Gel range features a rechargeable, deep cycle, Valve Regulated Lead Acid (VRLA) battery. Gel technology varies from its AGM counterpart because the electrolyte is suspended in Thixotropic Silica Gel, unlike the AGM batteries where the electrolyte is suspended in the Absorbent Glass Mat. Genuine Gel technology gives the Valen Gel range an edge over its competition by extending the longevity of the battery and minimising the number of cycles the battery requires to reach its full capacity.

The Valen Gel battery range has met and exceeded all market expectations over the years and continues to prove its excellence thanks to its ability to resist deep discharges and to recover after heavy draining. Stringent quality controlled manufacturing and in-house testing allows the Valen Gel battery to deliver a 10-year design life and can be the economical battery of choice in cyclic applications.

Voltage 6 & 12 Volt nominal
Plates Heavy Duty
Container ABS Plastic
Charge Voltage 6V Cycle: 7.2-7.5V at 25°C
6V Float: 6.75-6.9V at 25°C
12V Cycle: 14.1-14.4V at 25°C
12V Float: 13.5-13.8V at 25°C
Design Life 10-years
Electrolyte Thixotropic Gel – Sulphuric Acid
Vent Self-sealing
Operating Temp* -20°C to +60°C

* However Valen recommend the GEL batteries be operated in the temperature range of 20°C to 30°C to obtain full life and optimum performance.

Valen Gel range features a rechargeable, deep cycle, Valve Regulated Lead Acid (VRLA) battery. Gel technology varies from its AGM counterpart because the electrolyte is suspended in Thixotropic Silica Gel, unlike the AGM batteries where the electrolyte is suspended in the Absorbent Glass Mat. Genuine Gel technology gives the Valen Gel range an edge over its competition by extending the longevity of the battery and minimising the number of cycles the battery requires to reach its full capacity.

The Valen Gel battery range has met and exceeded all market expectations over the years and continues to prove its excellence thanks to its ability to resist deep discharges and to recover after heavy draining. Stringent quality controlled manufacturing and in-house testing allows the Valen Gel battery to deliver a 10-year design life and can be the economical battery of choice in cyclic applications.

Gel Range

Filter by:

Filters
Product Range

Volt: 6 V

Cap: 225 Ah

In Stock

Voltage6 V
SKUR6VG225
TerminalM8
Length243 mm
Width188 mm
Height275 mm
C20220 Ah
C10210 Ah
C5178 Ah
Capacity225

Download Information Sheet

Volt: 6 V

Cap: 225 Ah

In Stock

Voltage6 V
SKU6VG225
TerminalM8
Length243 mm
Width188 mm
Height275 mm
C20220 Ah
C10210 Ah
C5178 Ah
Capacity225

Download Information Sheet

Volt: 12 V

Cap: 21 Ah

In Stock

Voltage12 V
SKU12VG21
TerminalM5
Length181 mm
Width77 mm
Height167 mm
C10C5/13.2Ah Ah
Capacity21
Box Quantity2

Download Information Sheet

Volt: 12 V

Cap: 26 Ah

In Stock

Voltage12 V
SKU12VG26
TerminalM6
Length165 mm
Width125 mm
Height175 mm
C10C5/20.1Ah Ah
Capacity26

Download Information Sheet

Volt: 12 V

Cap: 33 Ah

In Stock

Voltage12 V
SKU12VG33
TerminalM6
Length195 mm
Width130 mm
Height158 mm
C10C5/24Ah Ah
Capacity33

Download Information Sheet

Volt: 12 V

Cap: 40 Ah

In Stock

Voltage12 V
SKU12VG40
TerminalM6
Length197 mm
Width165 mm
Height158 mm
C10C5/32.5Ah Ah
Capacity40

Download Information Sheet

Volt: 12 V

Cap: 55 Ah

In Stock

Voltage12 V
SKU12VG55
TerminalM6
Length229 mm
Width138 mm
Height214 mm
C2055 Ah
C542.6 Ah
Capacity55
Box Quantity1

Download Information Sheet

Volt: 12 V

Cap: 60 Ah

In Stock

Voltage12 V
SKU12VG60
TerminalM6
Length254 mm
Width168 mm
Height178 mm
C2060 Ah
C552 Ah
Capacity60

Download Information Sheet

Volt: 12 V

Cap: 70 Ah

In Stock

Voltage12 V
SKU12VG70
TerminalM6
Length254 mm
Width168 mm
Height205 mm
C2070Ah Ah
C1064.8Ah Ah
C554.2Ah Ah
Capacity70
Box Quantity1
NATO Stock Number (NSN)NATO Stock Number (NSN) - 6140 66 167 0302

Download Information Sheet

Volt: 12 V

Cap: 100 Ah

In Stock

Voltage12 V
SKU12VG100
TerminalM8
Length330 mm
Width173 mm
Height215 mm
C10C5/77.4Ah Ah
Capacity100

Download Information Sheet

Ideal applications include

  • Premium (Valve Regulated Lead Acid) VRLA Design
    Valen GEL battery range is able to be installed and operated in any position (except inverted) making it an attractive option for less accessible areas
  • Maintenance Free Design
    Minimises technician time spent at site and on battery related callouts
  • Advanced Thixotropic Silica Gelled Electrolyte
    Genuine Gel separators and quality lead plates allow the Valen GEL battery range to offer a 10-year design life
  • FAA and IATA Approved
    Valen GEL battery range is safe for air transportation

Enquire Now

Login Required

An account is required to add products to your cart, please login or register for an account.