Valen ENDUROGEL 2V500Ah Battery

SKU: 2EG500

Valen ENDUROGEL 2V 500Ah VRLA gel cell with a Catalyst Life Extender for long service life in UPS, data centre, comms and solar systems.

The Valen ENDUROGEL 2V500Ah Battery features a rechargeable, deep cycle, Valve Regulated Lead Acid (VRLA) battery. Genuine Gel technology allows this range to offer the cyclic benefits of the Valen Gel battery range.
However, the Valen ENDUROGEL 2V500Ah Battery outshines the standard Gel battery by incorporating both advanced lead plates and the Catalyst.
High purity virgin lead plates with 1.6% tin extend the longevity of the Valen ENDUROGEL 2V500Ah Battery. The inclusion of the unique Catalyst Life Extender reduces sulphation and delamination while substantially preventing battery dry out.
The Valen ENDUROGEL 2V500Ah Battery configuration allows for safe and secure installation and maintenance especially prevalent in higher capacity cyclic power systems. Stringent quality controlled manufacturing and in-house testing gives the Valen ENDUROGEL 2V500Ah Battery the ability to deliver a 20-year design life, as well as being the 2V battery of choice in demand

Price

+GST

Qty

Features

Premium Valve Regulated Lead Acid (VRLA) Design Valen Gel battery range can be installed and operated in any position (except inverted) making it an attractive option for less accessible areas Maintenance-Free Design Minimises technician time spent at site and on battery related callouts Advanced ENDUROGEL Technology Thixotropic Gelled electrolyte, genuine Gel separators, quality lead plates, and a Catalyst Life Extender allow the Valen ENDUROGEL range to offer a 15-year design life Unique Catalyst Life Extender Prevents battery dry out allowing the Valen ENDUROGEL range to become the battery of choice for mission-critical cyclic applications Specialised Valen 2V Design Includes a protective terminal cover as well as insulated intercell links Racking Available Standard racking is available. Valen provides customised racking ensuring that there is always a solution to fit your site FAA and IATA Approved Valen ENDUROGEL battery range is safe for air transportation

Applications

UPS Comms Datacentre Mining Rail Solar

Specifications

Voltage2 V
SKU2EG500
TerminalM8
Length241 mm
Width171 mm
Height330 mm
C20528 Ah
C10500 Ah
C5433 Ah
Capacity500
Box Quantity1

Downloads

Related Products

Valen ENDUROGEL 12V300Ah Battery

Valen ENDUROGEL 12V300Ah Battery

Volt: 12 V
Cap: 300 Ah
In Stock
Valen ENDUROGEL 12V60Ah Battery

Valen ENDUROGEL 12V60Ah Battery

Volt: 12 V
Cap: 60 Ah
In Stock
Valen ENDUROGEL 12V50Ah Battery

Valen ENDUROGEL 12V50Ah Battery

Volt: 12 V
Cap: 50 Ah
In Stock
Valen ENDUROGEL 2V 450Ah Battery

Valen ENDUROGEL 2V 450Ah Battery

Volt: 2 V
Cap: 450 Ah
In Stock
Valen ENDUROGEL 12V170Ah Battery

Valen ENDUROGEL 12V170Ah Battery

Volt: 12 V
Cap: 170 Ah
In Stock
Valen ENDUROGEL 12V110Ah Battery

Valen ENDUROGEL 12V110Ah Battery

Volt: 12 V
Cap: 110 Ah
In Stock
Valen ENDUROGEL 12V80Ah Battery

Valen ENDUROGEL 12V80Ah Battery

Volt: 12 V
Cap: 80 Ah
In Stock
Valen ENDUROGEL 2V1000Ah Battery

Valen ENDUROGEL 2V1000Ah Battery

Volt: 2 V
Cap: 1000 Ah
In Stock
Valen ENDUROGEL 12V220Ah Battery

Valen ENDUROGEL 12V220Ah Battery

Volt: 12 V
Cap: 220 Ah
Low Stock

Frequently Asked Questions

What is the difference between cycle use and standby use?

Standby (float) use: the battery sits fully charged on a charger and discharges rarely, UPS, telecom reserve, substation tripping supply. Life is governed by calendar ageing, temperature and float voltage. Cycle use: the battery is…

Full answer: What is the difference between cycle use and standby use?

What is the difference between AGM and gel batteries?

Both are VRLA, valve regulated lead acid, meaning sealed valves and immobilised electrolyte with internal gas recombination, so they do not require watering and can be installed in a wider range of locations than a…

Full answer: What is the difference between AGM and gel batteries?

How many cycles will a battery deliver?

Inversely related to depth of discharge. A typical VRLA discharged to 100% of capacity each cycle manages around 300 cycles; the same battery at 30% depth of discharge manages around 800. LiFePO₄ is a different…

Full answer: How many cycles will a battery deliver?

What ventilation does a battery room or enclosure need?

VRLA vents hydrogen under over-charge and high temperature; hydrogen is flammable above roughly 4% in air. Requirements sit in AS 2676 and AS 3011. A sealed IP-rated cabinet containing a battery bank with no designed…

Full answer: What ventilation does a battery room or enclosure need?

What does AS 2676 require for battery maintenance and testing?

[AS 2676 requirements · battery maintenance standard Australia] AS 2676 covers installation, maintenance, testing and replacement of secondary batteries in buildings, in two parts (vented and sealed cells). It is the standard Australian asset owners…

Full answer: What does AS 2676 require for battery maintenance and testing?

More Battery fundamentals FAQs

Enquire Now

Login Required

An account is required to add products to your cart, please login or register for an account.