The maintenance regime for a ModX2 is built around minimising site visits rather than eliminating them:

Interval

Activity

Quarterly

Visual inspection

Six-monthly

Electrical connections, battery health check, firmware currency

Annually

Solar panel cleaning, enclosure seals and filters, comprehensive service

Two practical points matter more than the schedule itself. First, most of what a quarterly visual inspection used to catch is now visible remotely, generation trend, state-of-charge behaviour, alarm history and load drift all show up in the monitoring data, which lets you convert calendar-based visits into condition-based ones and cut the number of trips.

Second, keep the logbook. Where a warranty depends on evidence of correct operation, the service record and the monitoring log are the claim. Abnormal findings should be reported promptly, because a fault left running is a fault the warranty may not cover.

More questions on this topic

Supplied as an integrated, factory-tested unit: the solar array on its certified fixed frame, the LiFePO₄ battery modules, solar charge control, inverter and DC-DC conversion, the monitoring controller, and the stainless steel enclosure with 4RU or more of designated space for your own equipment. It arrives pre-wired and tested, with structural certification documentation.

Supplied by others, and worth budgeting for early:

  • A level, certified concrete slab with chemical anchors. ModX2 mounts to a prepared foundation. Pre-engineered foundation designs are available as an option.
  • The earthing electrode and its cable to the internal earth bar, targeting under 10 ohms.
  • Site access suitable for a crane or lifting equipment. The unit lifts with batteries in place via integral lifting eyes, at a minimum 60° lift angle, and a spreader bar is recommended.
  • Freight and delivery, quoted separately.
  • Installation, connection and commissioning by a licensed electrical worker.

The weight of a three-battery configuration is approximately 480 kg, with overall dimensions of 2183 mm × 850 mm × 811 mm excluding the solar array. Confirm crane access and slab design against those figures before order.

No. ModX2 is an off-grid platform. It powers an isolated load at a site with no grid connection. It is not designed for grid-connected operation or for exporting power under a feed-in tariff.

If your site is already connected to the grid and you want to reduce bills or export surplus, that is a grid-interactive solar installation—a different product category entirely.

If your site has an unreliable grid and you need to keep running when it fails, talk to us about Vantara. It can be configured as a hybrid: running on grid when it is there, switching seamlessly to battery and generator when it is not.

We spell this out because specifying off-grid equipment into a grid-connected application creates a compliance headache after installation. Worth getting the category right upfront.

 

ModX2

Vantara

V-Trail

Type

Fixed frame, factory-certified

Fixed, large-scale modular SAPS

Towable hybrid SAPS

Continuous load

Up to 1,000 W AC plus 280 W DC

30 kVA per inverter, scalable to 90 kVA

Up to 30 kVA

Storage

5.12–15.36 kWh

55 kWh, expandable in 25 kWh steps

43 kWh nominal / 41 kWh usable

Best for

Unmanned remote infrastructure, SCADA, comms, CCTV, telemetry, ITS

Permanent site, community or facility-scale supply; DNSP SAPS

Temporary, emergency and redeployable power

Choose it when

The load is small, the site is permanent, and compliance documentation matters

The load is large, the site is permanent, and redundancy matters

The requirement moves, or is measured in weeks

Don’t choose it when

Continuous AC load exceeds 1,000 W

The site is temporary, or access prevents ground installation

You need a permanent fixed installation

The fastest way to get to the right answer is to bring three numbers to the first conversation: daily energy consumption in kWh, peak and surge load in kW, and how long the site needs to survive with no generation. Everything else follows from those.

Valen Power also offers ModX1 for smaller off-grid monitoring loads, Vantara Rapid for standardised multi-site rollouts, and Vora and VoraPlus batteries for grid resilience and community storage.

ModX2 is integrated, assembled and tested at Valen’s facility at Lawson, New South Wales, using componentry from established manufacturers. Valen Power is certified to ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018, and spares are held in Australia.

On a remote site four hours from a depot, Australian assembly buys you response time. A spare part dispatched locally instead of an import lead time. Support in your timezone. Warranty administration handled by the people who sold you the system, not routed offshore. And engineering support from the team that integrated the unit. That matters more than the flag on the paperwork.

Yes to both, with different degrees of effort. Battery capacity scales from one to three modules within the existing enclosure, so a site whose load grows, an extra camera, a comms upgrade, additional telemetry, can be uprated without replacing the system. Additional solar arrays are available as an option where generation rather than storage is the constraint.

Relocation is straightforward mechanically: the unit is designed to be lifted with batteries in situ, so a move is a crane, a transport permit and a new slab rather than a decommissioning exercise. That is a meaningful consideration for temporary construction, exploration and monitoring campaigns where the asset outlives the site.

Where relocation is the primary requirement rather than an occasional one, V-Trail is the better platform. It is trailer-mounted and designed to be towed and redeployed repeatedly.

Enquire Now