We power what can't fail

Energy Storage Solutions

FAQs

Systems: stand-alone power, off-grid and deployable

More questions on this topic

Frequently, yes, and the crossover point is closer than most asset planners assume. Rural network extension and replacement in Australia is commonly costed in the range of tens of thousands to hundreds of thousands of dollars per kilometre depending on terrain, access, vegetation and line construction standard. A SAPS is a fixed cost per site. Where a single customer sits at the end of several kilometres of line, the SAPS is usually the cheaper option on capital cost alone, before any operating saving.

The operating case is often larger than the capital case, and it is the part that gets under-counted:

  • Vegetation management on the removed line, in perpetuity
  • Inspection and maintenance of poles, conductor and pole-top assets
  • Fault response to a line that is long, remote and slow to patrol
  • Bushfire and storm exposure, both the risk cost and the mitigation cost
  • Reliability penalties, every hour of outage on that feeder is counted

Standalone power systems are reducing outage hours by around 90% on remote properties. Pilot programs have cut outage durations from 1,000 hours over five years on individual sites down to 72 hours. Long-term network scenarios contemplate deployments of thousands of units, removing tens of thousands of poles and tens of thousands of kilometres of conductor.

Multiple DNSPs are targeting 400+ SAPS installations across their networks by 2029. The economics are straightforward: a SAPS costs less than extending, maintaining and operating remote lines indefinitely.

The number that decides it on any given feeder is line length per customer. If you can send us that, plus the customer’s load profile, we can size the system.

The published evidence supports it. Western Power has installed more than 320 SAPS units, with a long-run scenario of around 4,000, removing roughly 50,000 poles and 23,000 km of conductor, and reports outages on SAPS-served properties down by around 90%. Essential Energy is targeting 400 SAPS by 2029.

A stand-alone power system for mining, or SAPS, generates and stores electricity at the point of use instead of taking supply from the distribution network. In Australian utility practice it typically combines solar generation, lithium battery storage, an inverter that produces standard 230/240 V AC, an energy management system, and often a small backup generator, all installed at the site it serves, with no connection to a distribution feeder.

SAPS are used in two distinct ways in Australia, and it is worth being clear which one you mean. Distributor-led SAPS replace an existing network connection: a DNSP identifies a long, low-customer-density feeder, often a single property at the end of several kilometres of line, and substitutes a SAPS for the poles and wire. Site SAPS power infrastructure that never had a grid connection at all: remote telecommunications, water pumping, mine infrastructure, monitoring stations, rail trackside assets.

The engineering is similar. The commercial case, the regulatory treatment and the reliability standard applied are quite different. Vantara is built for both, but the sizing conversation starts differently depending on which you are doing.

Technically they overlap; commercially they are different products for different buyers. “Off-grid solar” generally describes a system serving a premises that chose not to connect. “SAPS” is the utility and infrastructure term, and it carries expectations that off-grid solar usually does not: a defined reliability standard, redundancy, remote monitoring, SCADA integration, and in the distributor-led case a regulatory framework governing the customer’s rights. Same physics, different specification.

Parasitic load is the energy the system consumes to run itself, cooling, inverter standby, communications, controls, before any of it reaches your load. It is the most commonly ignored specification in off-grid procurement and one of the most consequential, because on a small remote load it can be a large fraction of daily generation.

Vantara’s parasitic loads:

Component

Draw

HVAC

0.41 kWh

Inverters (2 units, approximately 60 W each)

0.12 kWh

Communications

0.007 kWh

Other

0.06 kWh

Inverter maximum efficiency is 96%; MPPT efficiency on the solar charge controllers is 99.90%.

When comparing systems, ask two questions that vendors rarely volunteer: what is the total daily parasitic consumption in kWh, and is the quoted usable storage before or after parasitic draw. A system with 10% higher nameplate storage and double the parasitic load can deliver less energy to your equipment. On a site where you are paying for every kWh of solar and storage, that difference compounds directly into capital cost.

 

ModX2

Vantara

V-Trail

Type

Fixed frame, factory-certified

Fixed, large-scale modular SAPS

Towable hybrid SAPS

Continuous load

Up to 1,000 W AC plus 280 W DC

30 kVA per inverter, scalable to 90 kVA

Up to 30 kVA

Storage

5.12–15.36 kWh

55 kWh, expandable in 25 kWh steps

43 kWh nominal / 41 kWh usable

Best for

Unmanned remote infrastructure, SCADA, comms, CCTV, telemetry, ITS

Permanent site, community or facility-scale supply; DNSP SAPS

Temporary, emergency and redeployable power

Choose it when

The load is small, the site is permanent, and compliance documentation matters

The load is large, the site is permanent, and redundancy matters

The requirement moves, or is measured in weeks

Don’t choose it when

Continuous AC load exceeds 1,000 W

The site is temporary, or access prevents ground installation

You need a permanent fixed installation

The fastest way to get to the right answer is to bring three numbers to the first conversation: daily energy consumption in kWh, peak and surge load in kW, and how long the site needs to survive with no generation. Everything else follows from those.

Valen Power also offers ModX1 for smaller off-grid monitoring loads, Vantara Rapid for standardised multi-site rollouts, and Vora and VoraPlus batteries for grid resilience and community storage.

Autonomy is the number of days the system can carry the load with no solar generation at all. AS/NZS 4509.2, the Australian standard for stand-alone power system design, gives the guidance most Australian designers work to: 2 days where an automatic generator is fitted, 2–3 days with manual generator control, and 4–5 days for a solar, wind or hybrid system with no generation backup at all.

ModX2 is configured with one, two or three LiFePO₄ battery modules. As an indication, at a 100–200 W continuous load that gives roughly 1.5–2 days, 2.5–4 days and 4–6 days of autonomy respectively. Two modules is the standard configuration. Use the ModX2 calculator to enter your actual site loads and see the recommended battery configuration against your daily consumption.

Three things move those numbers. Any supplier who quotes autonomy without them is guessing:

  • The maximum contiguous run of low-solar days at your latitude and season
  • The capacity the battery will still have at end of design life, not when new
  • The actual measured load, not the estimated one For rail applications, note that AS 7703 clause 4.2.3 requires solar battery sizing to explicitly account for both the cloudy-day run and end-of-life capacity degradation, an estimate that ignores either will not survive design review.

No. A well-sized ModX2 solar and battery system can operate standalone indefinitely without one.

The case for including a generator comes down to three situations. First, where the load cannot be interrupted—a communications tower that must stay online, a pumping station that cannot stop mid-cycle. Second, where geography genuinely limits solar yield in winter, and the asset owner won’t accept manual load-shedding or seasonal downtime. Third, where you need a reliability number to defend to a regulator and want that margin baked in.

The case against is practical: a generator adds fuel logistics, service intervals, noise, and emissions to a site chosen partly because nobody wants to visit it.

If you do include one, size the array and battery for the reliability you need in a normal year, then treat the generator as an exception handler, not the daily workhorse. ModX2 can auto-start at 20% state of charge and auto-stop at 80%, with both thresholds adjustable. If the generator is running weekly, the system is undersized, and that’s worth revisiting.