ModX2 is sized for continuous loads in the 80 W to 1,000 W range, the band that covers almost all remote monitoring, control and communications infrastructure. It provides up to 1,000 W continuous AC with 2,400 W peak surge, plus an isolated DC path supporting up to 280 W for equipment that runs natively on 12 V or 24 V DC.
Typical measured site loads by application:
|
Application |
Typical continuous load |
|---|---|
|
SCADA, RTU and telemetry panels |
80–280 W |
|
Communications: GRN, PSN, repeaters, microwave |
100–200 W |
|
ITS roadside devices |
50–150 W |
|
CCTV, perimeter and access control |
50–150 W |
|
Environmental and structural monitoring |
20–150 W |
|
Cathodic protection and flow metering |
Site-specific |
If your continuous AC load exceeds 1,000 W, ModX2 is the wrong product. Vantara or V-Trail is the right platform. The most useful thing you can bring to a first conversation is the actual 24-hour energy consumption in kWh, not the nameplate rating of the equipment.