es, and lithium is often the better choice, but the cabinet’s thermal design, not the battery’s datasheet, decides whether it works.
VRLA loses roughly half its life expectancy for every 10 °C of sustained temperature above 20 °C, which is why a long-design-life VRLA becomes a short-lived consumable in a sun-loaded enclosure. LiFePOâ‚„ does not degrade on that curve. In a 40 °C-plus cabinet, lithium’s whole-of-life cost advantage is at its largest, and it is the reason Australian road authorities have increasingly specified LiFePOâ‚„ for roadside critical infrastructure.
Three things must be right:
- A maximum internal temperature. Industry standards require cabinets to hold internal temperature no higher than 50 °C, achieved with double-skinned construction, ventilation slots, thermostatically controlled fans, and white heat-reflective paint. SOLiCORE’s discharge range extends to 60 °C, but charging stops at 55 °C.
- A minimum internal temperature. Standards also require a minimum of 0 °C with a thermostatically controlled heater. This prevents charge inhibition at sub-zero temperatures and maintains battery responsiveness in alpine and high-altitude regions.
- A charge regime the BMS accepts, and coordination between the BMS cut-off and any plant-level low-voltage disconnect.
For any lithium installation inside an occupied structure, assume the fire engineering will be examined. Plan accordingly.