Interval |
Activity |
|---|---|
|
Monthly |
Visual inspection |
|
Quarterly |
Battery check; cooling and ventilation |
|
Six-monthly |
Solar cleaning; system health check |
|
Annually |
Firmware currency |
Plus the trailer itself: tyres, bearings, brakes, coupling and lights on a road-registrable schedule, and the generator on its own service hours rather than on a calendar.
Two things that matter more than the schedule:
Keep the logbook. V-Trail is supplied with a maintenance schedule and logbook template. Abnormal findings should be reported promptly, a fault left running is a fault the warranty may not cover. On a fleet asset that moves between crews and sites, the logbook is the only continuity there is.
Track generator service by run hours, not by calendar. A unit that spends most of its deployments on solar accumulates generator hours slowly; one working a high-load site accumulates them fast. Calendar-based generator servicing over-services one and under-services the other.